Particulate Transmitter: EM 30T
Transmitter |
|
Power Supply: |
From 4-20mA Loop |
Supply Voltage: |
18-24VDC |
Output: |
500Ohms Max at 24VDC |
Output Isolation: |
500VDC Process to Loop |
Resolution (Range): |
10.0pA (0-5000pA) Std, 5.0pA or 0.5pA Opt |
Temperature: |
-13F (-25C) to 160F (70C) |
General: |
Circuit boards conformal coated for long life in harsh environments |
Sensor |
|
Housing: |
NEMA 4X Aluminum Std |
Probe Lengths: |
3, 5, 10, 15, 20, 30, 36" (Approximately 1/2 duct/pipe I.D.)
Extended nipples & rope sensors for large multicompartment baghouses |
Mounting: |
NPT, Tri-Clamp or Flange |
Wetted Materials: |
316SS and Teflon or Ceramic Std Hastelloy Opt |
Process Temperature: |
250F/120C Std 450F/232C Opt |
Process Pressure: |
10PSI (.69bar) Std, 50PSI (3.45bar) Opt, 100PSI(6.9bar) Opt 2-piece only |
Sensor Cable: |
300’ (100m) Max (2-piece configuration only) |
Area Classification: |
Ordinary locations (CE Approved) Std
Class I, II & III, Div II Only (CSA Approved) Opt |
General: |
No special alignment, not affected by normal process vibration |
Application Range |
|
Particulate: |
Any type >0.3 micron - Conductive, non conductive, moist, corrosive |
Minimum Detection Level: |
With 10.pA resolution - Greater than 10mg/m3 (basic leak detection)
With 5.0pA resolution - Approx. 5-10mg/m3 (standard leak detection)
With 0.5pA resolution - Approx. 0.5mg/m3 (monitoring & analysis) |

Brochure | Application Review Form | Manual | Contact |