Home
Login
Company
Customer Support
Contact
 

Products

Particulate Detectors: Models EM 30A and EM 10A

Overview

 

Applications

 

Specifications

 

Specifications EM 30A

Electronics

 

Power Supply:

12-28VDC @ 3 watts

Output:

(2) Solid state relay @ 170mA, fixed set points

 

For adjustable 5A relays refer to Model EM 30LGX

Temperature:

-15F (-25C) to +160F (+70C)

General:

Circuit board conformal coated for long life in harsh environments

Probe

 

Lengths:

Heavy duty 3, 5 or 10” Std; 15, 20, 30, 36" Opt

Mount:

NPT Std, Tri-Clamp or Flange Opt

Wetted Materials:

316SS and Teflon Std, Hastelloy Opt

Housing:

Heavy duty NEMA 4X aluminum

Temperature:

250F Std (120C), 450F (232C) Opt

Pressure:

10PSI (0.69bar) Std, 50PSI (3.45bar) Opt

Area Classification:

Ordinary/general purpose, for hazardous areas refer to other models

Application Range

 

Particulate:

Any type >10 micron, Conductive, non-conductive, moist, corrosive

Minimum Detection Level:

10pA - Greater than 10mg/m3 (basic leak detection)

 

 


Specifications EM 10A

Electronics

 

Power Supply:

12-24VDC @ 3 watts

Output:

(2) Solid state relay @ 170mA, fixed set points

 

For adjustable 5A relays refer to Model EM 30LGX

Temperature:

-4F (-20C) to +140F (+60C)

General:

Circuit board conformal coated for long life in harsh environments

Probe

 

Length:

10” Light duty (shorten by customer if needed)

 

For longer probes refer to the EM 30A and other models

Mount:

1/2” NPT

Wetted Materials:

304SS

Housing:

Light duty NEMA 4X aluminum

Temperature:

180F (82C)

Pressure:

3PSI (0.2bar)

Area Classification:

Ordinary/general purpose, for hazardous areas refer to other models

Application Range

 

Particulate:

Dry Non conductive >10 micron

Minimum Detection Level:

10pA - Greater than 10mg/m3 (basic leak detection)

 

 

 

Brochure | Application Review Form | Manual | Contact