Liquid Mist Monitor: LM 70 DGX

Overview

 

Application

 

Specifications

 

Control Unit

 
Power supply: 115/230VAC 50/60Hz Std (6 Watts max) 24VDC Opt
Resolution (Range): 0.5pA (0 to 5000pA) Std 0.1pA (0 to 5000pA) Opt
Outputs: (2) Relay (SPST, 5A@240VAC) Std
(1) 4-20mA Isolated Std
Inputs: (1) Relay Opt
Communications: (1) Modbus RTU Opt or Ethernet IP Opt
Enclosure: NEMA 4X Aluminum Std Other Opt
Temperature: -13F (-25C) to 160F (70C)
User Interface: LCD with digital, analog & text display, 4 button membrane keypad
Area Classification: Ordinary locations (CE Approved) Std
Ordinary locations (CSA Approved for use with Class I, II, III sensor) Opt

Sensor
 
Housing: NEMA 4X Aluminum Std
Probe Lengths: 3, 5, 10, 15, 20, 30, 36, 48, 60, 72"
Mini probes down to 1/16" and non intrusive rings for small tubing
Mounting: NPT, Tri-Clamp or Flange
Wetted Materials: 316SS and Teflon or Ceramic Hastelloy Opt
Process Temperature: -40F (40C) to 250F (120C) Std 450F (232C) Opt 800-1200F Opt
Process Pressure: 10PSI (.69bar) Std, 100PSI (6.9bar) Opt, 1000PSI (69bar) Opt
Sensor Cable: 300’ (100m) Max
Area Classification: Ordinary locations (CE Approved) Std
Class I, II, III, Div I, II, All Groups (Intrinsically Safe, CSA Approved) Opt
General: No special alignment, not affected by normal process vibration

 