Control Unit |
MICS™ Platform (Modular Instrumentation and Control System) |
Enclosure: |
NEMA 4X Aluminum Std Other Opt |
Temperature: |
-13F (-25C) to 160F (70C) |
User Interface: |
3.5" Industrial TFT display, Industrial membrane keypad |
Area Classification: |
Ordinary locations and hazardous areas pending |
|
|
Modules |
Snap in DIN rail type, 32bit DSP with internal CAN bus |
Power supply: |
115/230VAC 50/60Hz Std (6 Watts max) 24VDC Opt |
Particulate Modules (up to 32): |
5.0pA Std 0.5pA Opt or DynaCharge™ 0.1pA Processor Opt |
Fieldbus Modules: |
Modbus RTU, Ethernet TCP, Ethernet IP, DeviceNet, Profibus, CanOPEN |
SD Memory Card: |
Field support memory card Std, Data logging card Opt |
Relay/Analog I/O Modules: |
Mixed relay/analog, relay only and analog only (Refer to price sheet) |
|
|
Sensors |
Remote passive sensors, not affected by alignment or normal vibration |
Housing: |
NEMA 4X Aluminum Std |
Probe Lengths: |
3, 5, 10, 15, 20, 30, 36" (Approximately 1/2 duct/pipe I.D.)
Extended nipples & rope sensors for large multicompartment baghouses |
Mounting: |
NPT, Tri-Clamp or Flange |
Wetted Materials: |
316SS and Teflon or Ceramic Hastelloy Opt |
Process Temperature: |
-40F (-40C) to 250F (120C) Std 450F (232C) Opt 800-1600F Opt |
Process Pressure: |
10PSI (0.69bar) Std, 50PSI (3.4bar), 100PSI (6.9bar), 1000PSI (69bar) Opt |
Sensor Cable: |
300’ (100m) Max |
Area Classification: |
Ordinary locations and hazardous areas pending |
|
|
Application Range |
|
Particulate: |
Any type >0.3 micron - Conductive, non-conductive, moist, corrosive |
Minimum Detection Level: |
With 5.0pA resolution - Approx. 5-10mg/m3 (standard leak detection)
With 0.5pA resolution - Approx. 0.5mg/m3 (monitoring & analysis)
With 0.1pA DynaCharge Processor - Approx. 0.1mg/m3 (mass correlations) |